12 Patient Monitor
Code ID: Moni 8D
Model ID: Moni 8D
Certificate: ISO, CE, FDA
Min. Order: 5 PCS
Inquire
Print
 
Feature:
Displayer: 12.1" color TFT LCD screen with maximum 8-waveform display. Adjusting of lightness continuously make patient more comfortable in midnight
 
◇ Displayer: 12.1" color TFT LCD screen with maximum 8-waveform display.
◇ Battery: Rechargeable high-energy built-in battery
◇ Advanced streamline outline design, portable, compact, lightweight
◇ Operating menu with multi-language interface selection: English, Spanish, Portuguese, Chinese, French, Arabic, Russian, etc.
◇ Easy operation with user friendly menu structure design and rotary dial
◇ Against electrosurgical interference and defibrillation and no need to disconnect the monitor from the patient in process of defibrillating.
◇ WAN communication function to network with central monitoring system and make long-distance monitoring, diagnosis, maintenance and software upgrade possible
◇ Optional built-in wireless networking function
◇ Support external printer to record graph and trend
◇ Intelligent audio and visual comprehensive alarm
◇ In-hospital applications include emergency pre-and post-operative care, ambulatory surgery, intermediate care/step down units, labor and delivery, and hospital-based special procedure areas.
◇ Suitable for use in physicians’ offices, clinics, outpatient surgical centers, extended care facilities and other patient care areas, which of require affordable monitoring
 
Specification:

◆Non-invasive blood pressure
◆Temperature
Measurement type:
adult, pediatric, neonate
 Measurement range:25.0℃-45.0℃
Measurement
range:
Systolic
Diastolic
Mean
4.0 - 37.0 kPa
1.3 - 33.0 kPa
2.6 - 35.0 kPa
 Accuracy: ± 0.1 ℃
Accuracy : ± 0.4 kPa or ± 2% 
Resolution: 0.1 ℃
Resolution: 0.1 kPa
response time: ≤ 3 min.
Protection: over pressure
◆ECG
◆Respiration Rate
Input: 5 wires ECG cable
Measurement range: 0 - 120 BPM (adult)
Lead section:
Ⅰ,Ⅱ,Ⅲ/ aVR, aVL, aVF/ V
Accuracy: ± 1 BPM or 5 %
Gain (mm/mV):
1/4, 1/2, 1, 2, 4
Resolution: 1 BPM
Frequency response:
Diagnosis
Monitor
Surgery
0.05 - 100Hz
0.5 - 40 Hz
1.0 - 25 Hz
◆CO2
Sweep speed (mm/sec):
12.5, 25, 50
Measurement range:
0 %-10.0 % (ins CO2 and et CO2)
Heart rate range: 30-254 BPM
Accuracy:
± 2 mm Hg (< 5 % Measurement value)
Heart rate accuracy: ± 1 %
10 % (> 5 % Measurement value)
ST segment deviation analysis:
-0.8~+0.8mV
◆Pulse oximetry
ST accuracy: ±0.02mv
SpO2 measurement range: 0 - 100 %
Invasive blood pressure
Resolution: 1 %
Measurement range:
0~40kPa (0~300mmHg)
Pulse measurement range: 30- 254BPM
Channel: 2 channel
Accuracy: ± 2 %
Transducer sensitivity: 5MV/V/mmHg
Resolution: 1 BPM
Unit display: kPa or mmHg selectable
◆Environment
◆Power requirements
Operation
Storage
Input: 98~260 V AC, 50/60Hz
Temperature
0.5 - 40 ℃
-20 - 50 ℃
Consumption: ≤ 80VA
Relative humidity
≤ 80%
≤ 90%
◆Safety standard: IEC 60601-1
Quality System: ISO13485: 2003
CE approved

 
Configuration:
Standard configuration:
ECG, HR, PR, SpO2, ST analysis, RESP*2 (RA-LL impedance and nasal cavity), NIBP (with venous punch), TEMP*2(surface and rectal type), Drug dose calculation.
 
Optional configuration:
Wireless connection, Recorder and ETCO2, 2-IBP

 